Advances, Systems and Applications
From: Weighted average current method for active damping control based on grid voltage feed-forward
Related parameter | Value |
---|---|
Grid voltage effective value eg/V | 220 |
Grid voltage frequency f/Hz | 50 |
DC side bus voltage Vdc/V | 680 |
switching frequency fs/kHz | 20 |
Rated power P/kw | 12 |
Inductance at inverter side L1/uH | 500 |
Grid side inductance L2/uH | 600 |
Filter capacitance C/uF | 8 |