Advances, Systems and Applications
Scenario | Experiment type | 100 | 200 | 400 | 800 |
---|---|---|---|---|---|
Steady rise and fall (Demand Scenario 1) | Baseline (without fault injection) | Successful | Successful | Successful | Successful |
800 ms delay latency | Successful | Successful | Successful | 80% Successful (8 out of 10) | |
1600 ms delay latency | Successful | Successful | Successful | 70% Successful (7 out of 10) | |
Stepwise increase and decrease (Demand Scenario 2) | Baseline (without fault injection) | Successful | Successful | Successful | Successful |
800 ms delay latency | Successful | Successful | Successful | 60% Successful (6 out of 10) | |
1600 ms delay latency | Successful | Successful | Successful | 40% Successful (4 out of 10) |